Connecting the Strobe
E-16
1 Remove the connector cap from the sync cord, and check the
O-ring (strobe/camera or housing)
z Check the O-ring to make sure there are no scratches or debris, and apply
a light coating of the included silicon grease.
2 Remove the strobe’s connector cap
3 Align the convex part on the strobe’s
connector with the notch of the sync
cord’s connector, and then push it
straight in
4 Align 1 with the screws of the
strobe, and then rotate it until it stops
z Tighten it securely.
z When removing the sync cord, loosen 1
and while holding the base of the sync cord’s connector, pull the sync cord
straight out.
z Do not pull the cord.
5 Remove the housing’s bulkhead connector cap
6 Align the round mark on the sync
cord (or the notch of the tip) and the
round mark on the strobe bulkhead
(or the convex part on the inside), and
then push it straight in
7
Align the B part of the sync cord with
the screws of the strobe bulkhead,
and then rotate it until it stops
8 Rotate the C part of the sync cord
until it stops
z Tighten it securely.
z When removing the sync cord, loosen C first, then B, and then pull the
sync cord straight out holding onto A.
z Do not pull on the cord part.
CAUTION
z Do not touch the connector’s contact pins with fingers. Do not apply
silicone grease to the connector’s contact pins. If contaminated
accidentally, clean the pins by a cotton swab moistened with alcohol.
Marking
Notch 1
C
B
A
ys_110a_e_7.fm Page 16 Tuesday, July 15, 2008 11:29 AM
Comments to this Manuals